Articles, Books and Patents

Peer-reviewed articles (15 most recent)

1. Cao K, Atkins SK, McNally A, Liu J, Sucosky P. Simulations of Morphotype-Dependent Hemodynamics in Non-Dilated Bicuspid Aortic Valve Aortas. J Biomech. 2016; in press. http://dx.doi.org/10.1016/j.jbiomech.2016.11.024
2. Cao K, Sucosky P. Aortic valve leaflet wall shear stress characterization revisited: impact of coronary flow. Comput Methods Biomech Biomed Engin. 2016; in press. http://dx.doi.org/10.1080/10255842.2016.1244266
3. Atkins SK, McNally A, Sucosky P. Mechanobiology in Cardiovascular Disease Management: Potential Strategies and Current Needs. Front. Bioeng. Biotechnol. 2016; 4: 1-5. http://dx.doi.org/10.3389/fbioe.2016.00079
4. Cao K, Sucosky P. Computational Comparison of Regional Stress and Deformation Characteristics in Tricuspid and Bicuspid Aortic Valve Leaflets. Int J Num Meth Biomed Eng. 2016; in press. http://dx.doi.org/10.1002/cnm.2798
5. Atkins SK, Moore AN, Sucosky P. Bicuspid Aortic Valve Hemodynamics Does Not Promote Remodeling in Porcine Aortic Wall Concavity. World J Cardiol. 2016; 8: 89-97.
http://dx.doi.org/10.4330/wjc.v8.i1.89
6. Cao K, Sucosky P. Three-Dimensional Prediction of Regional and Temporal Wall Shear Stress Characteristics on Aortic Valve Leaflets. Comput Methods Biomech Biomed Engin. 2015; 8: 1-11. http://dx.doi.org/10.1080/10255842.2015.1052419
7. Cao K, Sucosky P. Effect of Bicuspid Aortic Valve Cusp Fusion on Aorta Wall Shear Stress: Preliminary Computational Assessment and Implication for Aortic Dilation. World J Cardiovasc Dis. 2015; 5: 129-40.http://dx.doi.org/10.4236/wjcd.2015.56016
8. Sun L, Sucosky P. Bone Morphogenetic Protein-4 and Transforming Growth Factor-Beta1 in Acute Valvular Response to Supra-Physiologic Hemodynamic Stresses. World J Cardiol. 2015; 7:http://dx.doi.org/331-43.10.4330/wjc.v7.i6.331
9. Seaman C, McNally A, Biddle S, Jankowski L, Sucosky P. Generation of Simulated Calcific Lesions in Valve Leaflets for Flow Studies. J Heart Valve Disease. 2015; 24: 115-125.
Atkins SK, Sucosky P. The Etiology of Bicuspid Aortic Valve Disease: Focus on Hemodynamics. World J Cardiol. 2014; 6: 1227-33. http://dx.doi.org/10.4330/wjc.v6.i12.1227
10. Seaman C, Sucosky P. Anatomic Orifice Area, Effective Orifice Area and Pressure Recovery in the Bicuspid Aortic Valve. Echocardiography. 2014; http://dx.doi.org/10.1111/echo.12720
11. McNally A, Akingba AG, Robinson EA, Sucosky P. Novel Modular Anastomotic Valve Device for Hemodialysis Vascular Access: Design and Preliminary Computational Hemodynamic Assessment. J Vasc Access. 2014; http://dx.doi.org/10.5301/jva.5000284
12. Atkins SK, Cao K, Rajamannan NM, Sucosky P. Bicuspid Aortic Valve Hemodynamics Induces Abnormal Medial Remodeling in Porcine Ascending Aortas. Biomech Model Mechanobiol. 2014;http://dx.doi.org/10.1007/s10237-014-0567-7
13. Seaman C, Akingba G, Sucosky P. Steady Flow Hemodynamic and Energy Loss Measurements in Normal and Simulated Calcified Tricuspid and Bicuspid Aortic Valves. J Biomech Eng. 2014;http://dx.doi.org/10.1115/1.4026575
14. Sun L, Rajamannan NM, Sucosky P. Defining the Role of Fluid Shear Stress in the Expression
of Early Signaling Markers for Calcific Aortic Valve Disease. PLoS ONE. 2013; 8: e84433.http://dx.doi.org/10.1371/journal.pone.0084433
15. Sun L, Chandra S, Sucosky P. Ex Vivo Evidence for the Contribution of Hemodynamic Shear Stress Abnormalities to the Early Pathogenesis of Calcific Bicuspid Aortic Valve Disease. PLoS ONE. 2012; 7: e48843. http://dx.doi.org/10.1371/journal.pone.0048843

Books and Chapters

1. Sucosky P. Hemodynamic Mechanisms of Bicuspid Aortic Valve Calcification and Aortopathy. In Molecular Biology of Valvular Heart Disease, Springer; 2014. http://dx.doi.org/10.1007/978-1-4471-6350-3_11
2. Sucosky P, Rajamannan NM. Bicuspid aortic valve: from bench to bedside. In Cardiac Valvular Medicine, Springer; 2012. http://dx.doi.org/10.1007/978-1-4471-4132-7_3
3. Sucosky P. Flow Transport Phenomena in Tissue Engineering: Flow Characterization and Modeling of Cartilage Development in a Spinner-Flask Bioreactor. 136 pages, ISBN 9783639162264, VDM Verlag Dr. Müller; June 2009.

Patents

Fortenberry J, Yoganathan AP, Sucosky P, Dasi LP, Paden M. Novel Fluid Management System for Accurate Continuous Hemofiltration in Extracorporeal Membrane Oxygenation. US Patent No. 8,206,594, issued 6/26/2012.

© 2016 MSCBL | All rights reserved